Spares and parts are still available for the CV350X, CV353X and CV553X. All pipe work, hoses and tools are interchangeable between each different machine. All of our machines need to be connected to a dedicated 20 amp circuit.
Please use mobile phones in landscape format to view the tables below or swipe the screen to move across the table.
Power Units
Model | HP | Motor | Debris Recovery Method | Airflow At 2" Opening | Air Watts | Overall Size In Inches | Spec Sheet |
---|---|---|---|---|---|---|---|
VX1000 | 4.8 | 2 x 2 Stage Bypass | 8 Gallon HEPA filter bag | 230 CFM | 1040 | D x W x H 11.5 x 17.5 x 39 |
VX1000 |
VX1000C | 4.8 | 2 x 2 Stage Bypass | 7 Gallon cyclonic | 230 CFM | 1040 | D x W x H 11.5 x 17.5 x 39 |
VX1000C |
Model | Photograph | Description |
---|---|---|
CV850 |
|
|
VX1000 |
|
|
VX1000C |
|
Bag Table
Part No | Photograph | Use With | Bags Per Pack | Description |
---|---|---|---|---|
391 | CV350, CV352, CV353, CV450, CV653 & CV750. | 3 per pack | Two ply electrostatically charged filter media captures particles down to 0.10 micron at 85% efficiency. | |
391-8 | CV850 and suitable for CV450 & CV750. | 3 per pack | Two ply electrostatically charged filter media captures particles down to 0.10 micron at 85% efficiency. | |
VX391-8 | VX550 & VX1000. | 3 per pack | HEPA filter media offers the ultimate in filtration efficiency and superior air flow with minimum clogging. |
Warranty for the machines is only valid when the machines are used for domestic use and under the manufacturers guide, warranty is also for parts only NOT labour.
[top]
Low Voltage Hoses
Model | Photograph | Description |
---|---|---|
372 |
|
|
CH115 |
|
High Performance Low Voltage Hoses - With On/Off Fingertip Control
Model | Photograph | Description |
---|---|---|
CH230 |
|
|
CH230L |
|
|
CH235 |
|
[top]
Tool Kits
Model | Photograph | Description |
---|---|---|
CK110 |
|
|
CK120 |
|
|
CK230 |
|
[top]
Inlet Kit Guides
These kits exclude pipe brackets and plaster guards. Number of inlets quoted excludes the inlet incorporated with the machine. Full credit will be given for fittings returned unused.
Inlet Kits Guide | Approx.sq.ft |
---|---|
502 - 2 inlet installation kit | 700-1400 |
503 - 3 inlet installation kit | 1400-2100 |
504 - 4 inlet installation kit | 2100-2800 |
505 - 5 inlet installation kit | 2800-3500 |
506 - 6 inlet installation kit | 3500-4500 |
507 - 7 inlet installation kit | 4500-5500 |
508 - 8 inlet installation kit | 5500-7500 |
Inlet Installation Component Kit
Includes standard white inlets. Prices do not include carriage, VAT or installation costs.
Part No. | Description | 2 InletN502 | 3 InletN503 | 4 InletN504 | Vac Pan Kit |
---|---|---|---|---|---|
PRICE | Internet only | £70 | £90 | £135 | £60 |
N330W | White Inlet | 2 | 3 | 4 | |
N329 | Mounting Plate | 2 | 3 | 4 | |
NCI365 | VacPan (please specify colour) | 1 | |||
N382s | Tight 90 deg for use with N329 ONLY | 2 | 3 | 4 | |
N382xs | Very Tight 90 deg for Vac Pan ONLY | 1 | |||
N383 | 90 deg Branch | 1 | 2 | 3 | 1 |
N382/M377 | Medium and long sweep elbows | 6 | 10 | 12 | 4 |
N385 | 45 deg bend | 3 | 5 | 8 | 2 |
N388 | Couplings | 8 | 10 | 15 | 4 |
N328 | Plaster Guard | 2 | 3 | 4 | |
NCF380 | Pipe Support | 6 | 10 | 12 | 2 |
NA100 | Low Voltage Cable | 15m | 20m | 30m | 10m |
NC100 | Cable Ties | 16 | 20 | 32 | 10 |
N380-5 | 2" OD PVC Tubing 5ft Lengths | 40ft | 55ft | 80ft | 20ft |
Consider | Spare Package £10 | Spigot M/F Fittings | 2 each | N368 x 90° N369 x 45° |
[top]
Installation Supplies Described
GLUE: Not included Use regular PVC glue. Primer not needed.
Part No. | Photo | Description | Estimated Quantity per inlet valve. | Notes on what the part is for and other information. |
---|---|---|---|---|
N382S | Tight 90 Ell | 1 | Goes only on the mounting plate (that the inlet cover attaches to). It will be the tightest turn in the system and therefore catch anything long and stiff right at the inlet valve. | |
N382/377 | Sweep 90 Ell | 3 | The most used fitting for routing vac pipe around corners. The Sweep Ell has a more gradual 90 degree turn than the Tight 90 and should be used instead of the Tight 90 where ever possible. | |
N368 | Spigot Sweep 90 Ell | 1 | One end of a spigot fitting fits into another fitting. Great for tight spaces. | |
N385 | 45 Ell | 2 | Use these for offsets and thus use less Sweep 90's. | |
N369 | Spigot 45 Ell | 1 | One end of a spigot fitting fits into another fitting. Great for tight spaces and for offsets. Here is a plumber's secret - a regular 45 and a spigot 45 together can make any angle. | |
N388 | Coupling | 5 | Fits pipe sections together. | |
N383 | Sweep Tee | 1 | Connects a pipe coming from an inlet into the main truck line that runs back to where the vacuum power unit will be. You can use a "Y" fitting instead N387. | |
NCF380 | Pipe Strap | 3 | Pipe straps are used mostly to secure risers and when pipes are hung under joists. | |
N380-5 | Pipe: 5ft Lengths | 40ft | Vacuum pipe, tube, or tubing is made specifically for central vacuum systems. It is thin wall PVC with a 2-inch outer diameter fitting perfectly into vacuum fittings creating a smooth turn so no objects can "catch an edge". When gluing, use PVC cement on the pipe end only and push into the fitting with a slight turn. No glue residue will be inside the pipe. | |
N328 | Plaster Guards | 1 | Plaster guards are used in new construction installations. If you are short you could cut cardboard to protect the mount from the dry-wallers. | |
N329 | Back Plate | 1 | To secure inlet position. For new construction, nail it to a stud. When piping, connect a fitting such as a tight 90 to the flange. Finish it with a basic inlet valve cover. | |
N330W | Inlet | 1 | Styrene snap-back protective cover. Size: 3-1/2"W x 5-3/16"H x 1/2"D, installed. Install with 329 mounting plate. Other finishes available inc Brass and Chrome. | |
NI365 | Vac Pan Automatic Inlet. Back White or Cream | Automatic inlet installs in cabinet toekick or baseboard. Activates vacuum system automatically with the flip of toeswitch - allows you to sweep away dirt instantly. Great for kitchens, laundry rooms, mudrooms - wherever there is smooth flooring. Rough-in dimensions: 6-1/2" W x 4" D x 1-1/2" H, not including tubing. | ||
Wire Ties | Strap the low voltage wire to the pipe at each major elbow and every 4ft. |
[top]
For homes in excess of 12,000 square feet a specialist installation to incorporate more than one power unit can be designed.
You can download the NuTone brochure and Installation guide which are available in PDF format. If you are unable to download the documents you may require Adobe Acrobat.
NuTone® Central Vacuum Systems - Love Your Home
Great product, fantastic customer service. Always got products in stock for a quick dispatch. Mrs R.S A - Aberdeenshire
Each detail of the NuTone® Central Vacuum System's construction is driven by our obsession with perfection. With a NuTone® built in vacuum, you can clean everywhere around your home effortlessly and in record time. See your cleaning problems disappear.
There is a range of bags, hoses and tool kits available for your NuTone® Central Vacuum System to meet every need and requirement. Pipe work, hoses and tools are interchangeable between machines. All toolkits allow you to move from floor to carpet to curtains etc.
We supply all necessary pipe and fittings for any combination and number of inlets. We also provide handy installation kits with our recommended range of fittings for a given number of inlets. There are a number of different face plates to suit your chosen décor.